Water Intrusion Investigation at Chevalier Theatre – Medford, MA – August 2026
Gilrace Masonry Inc. completed a comprehensive water intrusion investigation at the historic Chevalier Theatre in Medford, Massachusetts, to identify the sources of ongoing water infiltration affecting the building.
Our team performed controlled water testing across multiple exterior elevations, including window assemblies, masonry joints, stone bands, and foundation walls.
Investigation and Findings
Through systematic testing, Gilrace Masonry identified several areas contributing to water penetration.
Deteriorated window assemblies allowed water to enter the building within approximately 5–10 minutes of testing. Open masonry joints and deteriorated stone band connections also permitted moisture to penetrate the exterior wall system.
Additional testing at the lower building elevation identified water infiltration through a boarded window opening and deteriorated joints where the concrete sidewalk meets the brick masonry.
Water reached interior foundation walls within approximately 15–20 minutes of controlled testing. Interior exploratory openings were also performed to document moisture conditions within wall assemblies and adjacent flooring areas.
Identifying the Source of Water Infiltration
By tracing the movement of water from exterior building components to interior areas, our investigation helped identify the specific locations requiring corrective attention.
This project demonstrates Gilrace Masonry’s experience in commercial water intrusion investigations, masonry assessments, controlled water testing, and building envelope diagnostics.